Mfg Part Number: CD2-A9-A16-DU | Alternate P/N: CD2A9A16DU |
NSN : 5925-01-161-2945 | NIIN : 011612945 |
CAGE Code : 74006 | Manufacturer: Reliance Comm Tec Corp |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
Thank you for choosing Civil Aviation Parts for part number CD2-A9-A16-DU. You have reached our NSN RFQ Page, featuring our top-requested NSN 5925-01-161-2945 parts and components with Circuit Breaker, manufactured by Reliance Comm Tec Corp. Some of these items include part number CD2-A9-A16-DU, and various others, all of which have been vetted for quality assurance and authenticity. At Civil Aviation Parts, we prioritize our customers and their operations by only sourcing from top global manufacturers that we trust, assuaging the worry of not receiving quality items from us.
The CD2-A9-A16-DU part number featured under the NSN 5925-01-161-2945 and manufactured by Navair And Navsea Managed are paired alongside CAGE Code 74006 under FSC 5925 Circuit Breakers. Civil Aviation Parts utilizes CAGE Codes so that our customers can narrow down our ever-expanding listings by using our optimized search engine and filters. If you are familiar with the CAGE Codes associated with the particular NSN products you wish to purchase, we invite you to use them.
If you need more information regarding the CD2-A9-A16-DU NSN item you wish to purchase, please include everything in the provided RFQ form below. When you fill out a form, in return, you will be provided a competitive quote for your comparisons in as little as 15 minutes.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-161-2945 Item Description: Circuit Breaker | 5925 | 011612945 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cd2-A9-A16-Du | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.769 INCHES MINIMUM AND 5.831 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.041 INCHES MINIMUM AND 2.103 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.516 INCHES MINIMUM AND 3.578 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.995 INCHES MINIMUM AND 1.057 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.719 INCHES MINIMUM AND 2.781 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.995 INCHES MINIMUM AND 1.057 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.172 INCHES MINIMUM AND 3.265 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CBBL | FEATURES PROVIDED | HIGH INRUSH PROTECTION |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 24.0 DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC FIRST LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT FIRST LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERVOLTAGE SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC FIRST LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SECOND LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 120.0 SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 FIRST LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT FIRST LOCATION AND 70.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
CRTK | SWITCH TERMINAL TYPE | TURRET |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 1.0 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
FREQ | FREQUENCY IN HERTZ | 50.0 FIRST LOCATION OR 60.0 FIRST LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 11.000 OUNCES |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
![]() |